Page 24 - Gemini Lakes Site Plan, Kolter
P. 24
SP-40
MATCHLINE - SEE SHEET EX-22 FOR CONTINUATION S POTABLE WATER DATE
CONNECTION
S
[]
SSMH-37 x
[]
EXISTING LIFT
[]
[]
MES-14 STATION
SSMH-38 SP-37
[]
[] MH-40-1
SP-38 EXSP-01
[]
POTABLE WATER EXSP-40-3-40-2 S S EXSP-40-14-40-1 MH 40-14
EXSP-02
[] DS-55 EXSP-40-2-40-1
CONNECTION DS-56 S S MH-40-2
[] [] S
[]
[] [] MH-40-1 S EXSP-40-14-40-15
S S
[] [] MH-40-3 S
EXSP-40-4-40-3 S S MH 40-15
EXSP-03
[]
[]
[]
S S COMMENTS REVISIONS
COUNTRY CLUB DR. DS-101 PROPOSED WET SANITARY SEWER
MH-40-4 S S
DS-100 DETENTION POND CONNECTION TRAVIS PL. 8 7 6 5 4 3 2 1
MES-100 EXISTING LIFT
SSMH-100 MES-103 STATION DWB DCM / AFR DWB / BAM 3/28/2025
PROPOSED FORCEMAIN MES-101 DS-153
CONNECTION S
DS-102
SSMH-108 EXDS-11
DS-103 DESIGNED CHECKED DATE ISSUED
SP-100
PALMER DR. JOB NO. DRAWN DATE
S
DS-152
S
SSMH-101 MES-102 CA#3728
SP-101 PROPOSED WET S SP-107
S
NELSON PL. DS-104 DS-105 S 1250 W. EAU GALLIE BLVD, SUITE H MELBOURNE, FLORIDA 32935 P: 321-253-1510 F:321-253-0911 ALSO WITH OFFICES IN: VERO: 772-569-0035, FT PIERCE: 772-468-9055, PALM CITY: 772-426-9959
DETENTION POND
S
MES-104
SSMH-102 DS-121 DS-120
OFFSITE STORMWATER
CONTRIBUTION MES-111
EXDS-14 EXDS-13 OFFSITE STORMWATER S
CONTRIBUTION
EXDS-15 S SSMH-109
SP-102 S
S
x
DS-109 DS-106 S S
DS-107 SP-108
ROYAL OAK DR. SSMH-105 DS-110 SSMH-103 MES-110 S LEGEND
SP-103
DS-122
DS-108
DS-123
S
SEWER PIPE
SSMH-110 SS PROPOSED SANITARY UTILITY EXHIBIT (SHEET 03 OF 04)
S
S
DS-111 SP-104 EXISTING WATER MAIN
S
SP-105 SSMH-104
SSMH-106
S
MES-105 S SP-109 EXDS-12 W PROPOSED WATER MAIN
PROPOSED LIFT
STATION EXISTING FORCEMAIN
OFFSITE STORMWATER
CONTRIBUTION S SP-106 PROPOSED WET SSMH-111 MATCHLINE - SEE SHEET EX-24 FOR CONTINUATION FM PROPOSED FORCEMAIN
SSMH-107 DETENTION POND PROPOSED WET
EXDS-16 LS-03 MES-106 DETENTION POND EXISTING REUSE MAIN
DS-112 DS-115
SP-121 S RW PROPOSED REUSE MAIN
DS-113
SP-110
SP-122 SSMH-122 x
DS-151 PROPOSED STORM PIPE
DS-114 MES-107 SSMH-117
PROPOSED WET PROPOSED WET FLORIDA
DETENTION POND
S
MES-31 DETENTION POND
MES-108 S S N
SP-120
SP-116
S
DS-119 S S
SSMH-121 SP-115
SSMH-118 DS-118 MES-112
GRAPHIC SCALE
x
DS-117 MES-109 DS-124 DS-126 100 0 0 50 100
S
SSMH-120 SP-117 DS-125 S GEMINI LAKES
SP-119
S
DS-116 S S SP-118 S S SSMH-116 S ( IN FEET )
SSMH-119 MES-113 1 inch = 100 ft.
PROPOSED WET SP-114 S S
S
DETENTION POND SP-113 SSMH-114 72 HOURS BEFORE DIGGING
CALL TOLL FREE
SSMH-115
x
R CITY OF TITUSVILLE
Know what'sbelow.
W:\25\25-1016 ROYAL OAK PD TITUSVILLE\06 CAD\Site\[25-1016] UTILITY.dwg 3/28/2025 10:44 AM DAVIDB
Call before you dig.
ROYAL OAK DR. MUNICIPAL APPROVAL STAMP PLAN SHEETS ARE PRELIMINARY AND FOR
NOT FOR CONSTRUCTION
INFORMATION ONLY. PLANS SHOULD NOT
BE USED AS A BASIS FOR BIDS.
CONTRACTOR SHOULD ORDER THE
OFFICIAL PLANS FROM THE ENGINEER OF
RECORD TO ENSURE THAT ANY
ADDENDUMS ARE PROPERLY DISTRIBUTED.
PLANS ARE INVALID WITHOUT ENGINEER
OF RECORDS SEAL AND SIGNATURE.
EXDS-22
KNOX MCRAE DR.
STORMWATER KNOX MCRAE DR.
OUTFALL
EXDS-21
EX-23
SHEET
PRELIMINARY SET